﻿{"id":782,"date":"2023-05-18T02:01:13","date_gmt":"2023-05-18T02:01:13","guid":{"rendered":"http:\/\/www.pod-eng.com\/?page_id=782"},"modified":"2023-05-19T01:59:37","modified_gmt":"2023-05-19T01:59:37","slug":"pumping-stations-rising-mains","status":"publish","type":"page","link":"http:\/\/www.pod-eng.com\/?page_id=782","title":{"rendered":"Pumping Stations &#038; Rising Mains"},"content":{"rendered":"<p><section data-kc-equalheight=\"true\" data-kc-equalheight-align=\"top\" class=\"kc-elm kc-css-284455 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-905369 kc_col-sm-4 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-4\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-408788 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-418239 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-860615 kc_text_block\"><\/p>\n<h2><strong>Water Pumping Station<\/strong><\/h2>\n<p>Pumping stations are necessary to transport water where there is an insufficient head. The capital cost of pumping station is high, but the most expensive part is the energy supply for pumps (mostly electrical). Therefore, it is very important that pumping station design have a high degree of efficiency and are maintained properly. The pumping station consists of water intake structures for suction pipes of pumps, the pumps themselves, motor, gear from motors to the pumps, pressure pipeline transporting water from the pumps to the water-discharge device, etc. Thus, the conception of a pumping installation includes all the components of the operation depends on the pump performance.<\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-723404 kc-feature-boxes kc-fb-layout-2\">\n\n\t<figure class=\"content-image\"><img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p62.jpg\" alt=\"\"><\/figure>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-58103 kc_col-sm-8 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-8\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-511189 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-548535 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-427953 kc_shortcode kc_single_image\">\n\n        <img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p63.jpg\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><section data-kc-equalheight=\"true\" data-kc-equalheight-align=\"top\" class=\"kc-elm kc-css-14858 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-479795 kc_col-sm-4 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-4\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-711455 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-127286 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-647903 kc_text_block\"><\/p>\n<h2><strong>POD methodology for conceptual and Preliminary Design<\/strong><\/h2>\n<p>\u27a3 Field visits and preparation of the report<br \/>\u27a3 Determination of pumping capacity based on existing and futured conditions and seasonal changes<br \/>\u27a3 Hydraulic calculation and optimizing pumping head and pipeline size<br \/>\u27a3 Optimizing number of pumping stations in case of high-pressure requirements and select design pumping TDH<br \/>\u27a3 Economical comparison of pumping station options as per cubic of water costs<br \/>\u27a3\u00a0 Reliability, flexibility, and simplest operation consideration<br \/>\u27a3 Selection of pump type based on mounting condition (submersible, dry horizontal, or dry vertical) as well as type of service (Boosting, Firefighting, Jockey, etc.)<br \/>\u27a3 Selection of pump category based on specific speed<br \/>\u27a3 Identifying the pump operating point based on pump performance curve and system curve with a priority of pump operation in BEP (Best Efficiency Point) condition\u27a3Assessment of available NPSH concerning required NPSH<br \/>\u27a3 Assessment of the static head variation (i.e. pumping from dams) and required VFD system as well as determination of pump performance curve for different speeds based on affinity laws<br \/>\u27a3 Determination of break power consumption and electro-motor selection<br \/>\u27a3 Assessment of water hammer and identifying required surge system<br \/>\u27a3 Assessment of hydrophore system in direct pumping to distribution networks<br \/>\u27a3 Identifying the required strainers or filtration<br \/>\u27a3 Identifying BFD \/ PFD<br \/>\u27a3 Preparation of preliminary pumping station arrangement<br \/>\u27a3 Preliminary CAPEX and OPEX estimation<br \/>\u27a3 Preparation of field surveys scope of the works (i.e. topographical maps, geotechnical investigation, water analysis)<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-952877 kc_col-sm-8 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-8\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-808492 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-848813 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-173449 kc_shortcode kc_single_image\">\n\n        <img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p64.jpg\" class=\"\" alt=\"\" \/>    <\/div>\n<div class=\"kc-elm kc-css-842692 kc_shortcode kc_single_image\">\n\n        <img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p65.jpg\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><section data-kc-equalheight=\"true\" data-kc-equalheight-align=\"top\" class=\"kc-elm kc-css-595914 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-909050 kc_col-sm-4 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-4\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-673626 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-428378 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-406120 kc_text_block\"><\/p>\n<h2><strong>POD methodology for Detailed Design<\/strong><\/h2>\n<p>\u27a3 Assessment of surveying, geotechnical investigations, and water analysis<br \/>\u27a3 Flooding risk assessment and protective solutions<br \/>\u27a3 Preliminary design review<br \/>\u27a3 Pumping station and sump tank arrangement<br \/>\u27a3 Mechanical design<\/p>\n<ul>\n<li>Mechanical details of piping and fittings<\/li>\n<li>Determination of pumping collector wall thickness<\/li>\n<li>Thrust block calculation<\/li>\n<li>Surge tank \/or hydrophore mechanical calculation<\/li>\n<\/ul>\n<p>\u27a3 Architectural design<br \/>\u27a3 HVAC system design<br \/>\u27a3 Firefighting system design<br \/>\u27a3 Structural design<br \/>\u27a3 Electrical &#038; Instrument design<br \/>\u27a3 Control philosophy<br \/>\u27a3 P &#038; ID<br \/>\u27a3 Site landscaping design<br \/>\u27a3Auxiliary budlings and units design<\/p>\n<ul>\n<li>Guard house<\/li>\n<li>Operation building<\/li>\n<li>Emergency diesel building and daily tank<\/li>\n<li>Substation<\/li>\n<li>Other buildings if required (Administration, Chlorination, Workshop, and Store)<\/li>\n<\/ul>\n<p>\u27a3 Utility design<\/p>\n<ul>\n<li>Potable water system<\/li>\n<li>Storm water system<\/li>\n<li>Site sewerage system<\/li>\n<li>Site surrounding fence<\/li>\n<li>Site green area<\/li>\n<\/ul>\n<p>\u27a3 3D-Modeling<br \/>\u27a3 Equipment specification<br \/>\u27a3 Civil work specification<br \/>\u27a3 MTO \/or BOQ<br \/>\u27a3 Preparation of tender documents if requested<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-398547 kc_col-sm-8 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-8\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-431111 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-697578 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-123138 kc_shortcode kc_single_image\">\n\n        <img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p68.jpg\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages\/782"}],"collection":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=782"}],"version-history":[{"count":8,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages\/782\/revisions"}],"predecessor-version":[{"id":864,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages\/782\/revisions\/864"}],"wp:attachment":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}