﻿{"id":792,"date":"2023-05-18T02:06:28","date_gmt":"2023-05-18T02:06:28","guid":{"rendered":"http:\/\/www.pod-eng.com\/?page_id=792"},"modified":"2023-05-19T02:48:26","modified_gmt":"2023-05-19T02:48:26","slug":"pumping-lifting-stations-rising-mains","status":"publish","type":"page","link":"http:\/\/www.pod-eng.com\/?page_id=792","title":{"rendered":"Pumping \/ Lifting Stations &#038; Rising Mains"},"content":{"rendered":"<p><section data-kc-equalheight=\"true\" data-kc-equalheight-align=\"top\" class=\"kc-elm kc-css-734740 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-226781 kc_col-sm-6 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-385178 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-577954 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-982839 kc_text_block\"><\/p>\n<h2><strong>Sewerage Pumping \/Lift Station<\/strong><\/h2>\n<p>Pumping stations are either in-line for pumping the sewerage from a deeper sewer line to a shallow sewer line or for conveying to the wastewater treatment plant or an outfall. They are also designed where sewerage from development areas or new collection networks when is not able to be drained by gravity to existing sewerage infrastructure, or where development areas are too far from available sewerage infrastructure to be connected by gravity conduits.<\/p>\n<p>Therefore, in the case of pumping sewer from a deep manhole to a shallow adjacent manhole, it is called lift station. In the other cases, to convey sewer to a far distance facility, it is categorized as pumping station. Although the technical criteria are similar, generally pumping stations required significant considerations such as the design and operation of force mains.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-539694 kc_col-sm-6 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-355456 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-599015 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-210623 kc_shortcode kc_single_image\">\n\n        <img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p76.png\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><section data-kc-equalheight=\"true\" data-kc-equalheight-align=\"top\" class=\"kc-elm kc-css-27720 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-54668 kc_col-sm-6 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-488159 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-155662 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-840242 kc_text_block\"><\/p>\n<h2><strong>Preliminary Study<\/strong><\/h2>\n<p>Design Flow, Min. &#038; Max. sewer flow, Run-off estimation, etc.<\/p>\n<p>Location and Configuration; Local topography, Size and type of the pumping station, Access considerations for O&#038;M needs including operators\u2019 health and safety issues, Visual impact, particularly the vent tube, odors, noise problems, etc., Vulnerability of the site to a natural and man-made disaster.<\/p>\n<p>Design of levels; Suction level, discharge level and top or bottom alarm levels<\/p>\n<h2><strong>Design of equipment<\/strong><\/h2>\n<p>Designing the equipment installed in the sewerage pumping station including; gates, screens, grit removal systems, conveyors, odor removal system and piping.<\/p>\n<h2><strong>Design of Pump<\/strong><\/h2>\n<p>Types of pumps, types of Pumping station &#038; number of Pumps; Due to the operation and maintenance costs, these parameters are considered one essential factor to design sewerage pumping stations. Proper type and number of pumps not only will provide a situation to operate effectively, but also save the energy consumption in any conditions and maintenance costs.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-218832 kc_col-sm-6 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-792391 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-801330 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-64765 kc_text_block\"><\/p>\n<h2><strong>Design of Instruments<\/strong><\/h2>\n<h4>The design of instruments in the pump stations includes;<\/p>\n<p>\u27a3 alarm system,<br \/>\u27a3 flow and pressure monitoring system,<br \/>\u27a3\u00a0the control system for best performance during the operation.<\/h4>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-332820 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-54362 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-973672 kc_text_block\"><\/p>\n<h2><strong>Main Types of Sewerage Pump Station<\/strong><\/h2>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/section><section data-kc-equalheight=\"true\" data-kc-equalheight-align=\"top\" class=\"kc-elm kc-css-942105 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-279747 kc_col-sm-3 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-3\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-325843 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-991847 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-421026 kc-feature-boxes kc-fb-layout-2\">\n\n\t<figure class=\"content-image\"><img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p77.png\" alt=\"\"><\/figure><div class=\"content-title\">Pumping station with horizontal pumps in dry-pit<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-45771 kc_col-sm-3 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-3\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-862600 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-557204 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-242207 kc-feature-boxes kc-fb-layout-2\">\n\n\t<figure class=\"content-image\"><img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p78.png\" alt=\"\"><\/figure><div class=\"content-title\">Main fields of experiencesPumping station with vertical pumps in dry-pit<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-159671 kc_col-sm-3 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-3\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-490393 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-450086 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-477031 kc-feature-boxes kc-fb-layout-2\">\n\n\t<figure class=\"content-image\"><img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p79.png\" alt=\"\"><\/figure><div class=\"content-title\">Pumping station with vertical pumps in wet-pit<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-891866 kc_col-sm-3 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-3\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-850586 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-716592 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-151476 kc-feature-boxes kc-fb-layout-2\">\n\n\t<figure class=\"content-image\"><img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p80-1.png\" alt=\"\"><\/figure><div class=\"content-title\">Pumping station with submersible sewerage pumps in wet-pit<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><section data-kc-equalheight=\"true\" data-kc-equalheight-align=\"top\" class=\"kc-elm kc-css-308683 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-942733 kc_col-sm-6 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-968847 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-236026 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-884872 kc_text_block\"><\/p>\n<h2><strong>Design of Pump<\/strong><\/h2>\n<p>Pump Selection the size and the numbers are challenging and it should be designed properly to serve the best performance in any flow conditions and provide the required head to transfer the flow with energy saving consideration. In the following figures, the system performance curve and pump curves are illustrated.<\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-79789 kc_shortcode kc_single_image\">\n\n        <img src=\"http:\/\/www.pod-eng.com\/wp-content\/uploads\/2023\/05\/p81.png\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"kc-elm kc-css-196265 kc_col-sm-6 kc-animated kc-animate-eff-fadeInUp kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-708782 kc_row kc_row_inner\"><div class=\"kc-elm kc-css-829175 kc_col-sm-12 kc_column_inner kc_col-sm-12\"><div class=\"kc_wrapper kc-col-inner-container\"><div class=\"kc-elm kc-css-962972 kc_text_block\"><\/p>\n<p>Designing a pump station just with one pump in operation required more volume for suction pit to store and equalize the flow in dry flow or wet weather conditions. Therefore, the constructional cost is increased dramatically. Although it seems the operation of one pump is more simpler, the total cost in the lifetime, the maintenance costs, energy cost, etc. would not be less than other options.<\/p>\n<p>Designing pump stations with multiple parallel pumps are more economic and practical in many aspects. For example, in case of minimum or average daily dry flow conditions, just one pump could be operated. In maximum flow, two pumps are in the service and in wet weather flow, three or more pumps may be considered to convey the flow. Therefore, due to less volume for suction chamber, the construction costs will be decreased and it provides a flexible situation for operation. On the other hand, increasing the number of pumps could be complicated for the operators and the more pumps, the more costs of operation and maintenance. Therefore, there is a technical challenge to balance the construction costs, operation and maintenance costs which could be overcome by an engineering concept. To conclude, the number of pumps is the main factor and it needs optimal design to consider all the aspects.<\/p>\n<p>On the other hand, designing pump stations with multiple parallel pumps is more economical and practical in many aspects. In minimum or average daily dry flow conditions, just one pump could be operated. In maximum flow, two pumps are in the service and in wet weather flow, three or more pumps may be considered to convey the flow. Therefore, the construction costs will be decreased and it provides a flexible situation for operation. To conclude, the number of pumps is the main factor and it needs optimal design to consider all the aspects.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages\/792"}],"collection":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=792"}],"version-history":[{"count":3,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages\/792\/revisions"}],"predecessor-version":[{"id":890,"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=\/wp\/v2\/pages\/792\/revisions\/890"}],"wp:attachment":[{"href":"http:\/\/www.pod-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=792"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}